14.4. Protection of electric contours
Various combinations of safety locks, fusible inserts and breakers of a chain are applied to protection of contact chains of electric equipment of the car. Assembly blocks, are installed in interior of the car and in a motive compartment of the vehicle.Safety locks
General information
Each separate safety lock is used for protection of any concrete electric contour or at once several contours. The ID card of placement of safety locks in the assembly block is usually applied on a cover of the last, from its outer side.
When replacing of the fused safety lock strictly you watch that the established replaceable corresponded on the type which left from an element. The safety locks calculated on various nominal current physically can differ in nothing from each other, without being at the same time interchangeable. Each of electric chains has various working parameters and needs various degree of protection therefore replacement of the safety lock calculated on a certain current, not corresponding to it in parameters is fraught with the most serious consequences (up to fire emergence). Working parameters of a safety lock (nominal current) are usually designated on its plastic case.
If the new safety lock at once after installation also fails, it does not make sense to make its further replacement, - before it is necessary to reveal and remove the cause of an overload in a chain. In most cases that appears the short circuit of a connecting electrical wiring caused by damage of its isolation.
Replacement
PERFORMANCE ORDER |
|||||||||||
|
Fusible inserts
General information and replacement
PERFORMANCE ORDER |
|
|
Chain breakers
General information
Breakers of a chain are used for protection of such components of system of onboard electric equipment as head headlights and electric motors of the drive of window regulators, activators of door locks, etc.
On some models after operation breakers revert to the original state automatically. If the overload which caused shutdown of the breaker had not incidental character, it is necessary to check a condition of the corresponding contour immediately. After malfunction elimination the chain breaker enters the normal mode of functioning again. Sometimes return of the breaker to the working condition should be made manually after elimination of the reason of an overload.